| Hardware | |
| Processor | Intel® IOP321 I/O processor: based on Intel XScale® technology, with hardware XOR. |
|---|---|
| Memory | Supports 32MB-512MB of PC1600 ECC DDR SDRAM (ships with 128MB DIMM installed). |
| PCI | 64-bit/133MHz PCI-X interface (PCI 2.2 and PCI-X 1.0 compliant), 3.3V adapter, backward compatible to 33MHz and 66MHz. |
| SCSI | Two-channel Ultra320 SCSI with support for up to 30 drives (15 per channel), each channel has one internal 68-pin connector (UHD LVD), and one external 68-pin connector (VHDC LVD). |
| Form Factor | Half-length, full-height PCI: 175mm x 107mm (6.875" x 4.2"). |
| Status Indicators | Audible alarm, LEDs. |
| Software | |
| RAID Levels Supported | 0, 1, 5, 10, 50 and JBOD. |
|---|---|
| Scalability | Online RAID-level migration and capacity expansion without reboot. |
| Configuration Flexibility | Variable data stripe size-configurable per array, configurable JBOD enclosure support, support for non-hard-disk-drive SCSI devices (for example, tape, CD-ROM), and read/write controller and disk caching. |
| Availability | Instant availability and background initialization, automatic rebuild with private (dedicated) or pooled (global) hot-fix (spare) drives, hot-plug drive support, and drive roaming. |
| Operating-System Support1 | |
| Standard Validation | Microsoft* Windows 2003 Enterprise Server; Microsoft Windows 2000 Advanced Server, Service Pack 4; Microsoft Windows XP; Novell* NetWare* 6.0; SCO OpenServer* 5.0.7 from Caldera*; Red Hat* Linux 8.0; Red Hat Linux 9.0; Red Hat Linux Enterprise Server 2.1; Caldera UnixWare* 7.1.3; SuSE* Linux 8.1 Professional; SuSE Linux Enterprise Server 8. |
|---|---|
| Environmental/Electrical/System | |
| Voltage Requirements | 3.3V (+/- 5% tolerance). |
|---|---|
| Power Requirements | 3.3V, 5V, 12V, -12V. |
| Ambient Temperature | Operating: 0°C to 55°C, non-operating: -40°C to 105°C. |
| Relative Humidity | 5% to 90% non-condensing. |
| Safety and EMC Regulatory Compliance (Class A) | EMC regulatory compliance is based on integration with a validated Intel® Server Board and configuration as outlined in the Intel® RAID Controller SRCU42X subassembly guide. |
| Australia and New Zealand | AS/NZS 3548 (C-Tick Mark). |
| Canada | CSA/UL 60950 / ICES-003 (cULus or NRTL Marking / ICES). |
| Europe | European Directives (CE Mark). |
| International | IEC 60950 / CISPR. |
| Korea | RRL (MIC Mark). |
| Taiwan | BSMI CNS (BSMI Mark). |
| United States | CSA/UL 60950 / FCC (cULus or NRTL Marking / FCC Mark). |
1 Operating-system support is contingent on the operating-system support of the motherboard in which this controller is installed.