Intel® Server Chassis SR2300 500-watt redundant power (RP) supply modules with Intel part number A76009-006 and prior revisions have the potential to fail during sustained, powered-on operation due to a failure of the primary PFC diode (D802) in the power supply module. If a diode failure occurs, systems operating in a non-redundant power supply configuration (only one power supply module installed in the power supply cage) will experience an immediate system power down. Systems operating in a redundant power supply configuration will continue normal operation, and the power supply module failure will be indicated by the power supply and system front panel status LEDs, and Intel® Server Management software.
TA674-5.PDF
Size: 19,604 bytes
Date: 2/20/2003 9:23 AM

Note: PDF Files require Adobe Acrobat* Reader†

† This link will take you off of the Intel Web site. Intel does not control the content of the destination Web Site.
This applies to:
|