Jumper Settings

The default jumper settings are correct for most installations.

The chassis intrusion detection jumper should be moved to "disable" if the Intel® N440BX Server Board will be used in a chassis that does not support a chassis intrusion sensor. To disable, move the chassis intrusion jumper to position 6-7.

If the chassis supports intrusion detection, the jumper should be moved to disable for any open chassis testing.

The Intel® Astor and Intel® Columbus II Server Chassis both incorporate a chassis intrusion sensor.

The Wake On LAN* "enable" jumper must be disabled if the feature is not desired or if your power supply is incapable of providing 800mA of +5V standby current.

Also see the discussion of Fault Resilient Booting (FRB), which is controlled by a board jumper.