When do updates take effect using the One Flash Update utility (OFU)?

The Intel® One Flash Update Utility (OFU) is used to update the BIOS and firmware on the Intel server boards while the operating system is running. The utility may be launched from a command prompt in either the Windows* or Linux* Operating Systems.

When the firmware update takes effect depends on whether or not the firmware is contained in one or two firmware blocks.

If the firmware component has two blocks, the Intel OFU utility will update the secondary area while the server continues to operate normally using the firmware in the primary area. In this case, the firmware will switch to the secondary bank on the next reboot.

If the firmware component is contained in a single block, the Intel OFU utility will update the firmware block and the firmware will immediately switch to the updated firmware.

The BMC boot block, Intel Local Control Panel, HSC, and FRU updates only have one firmware area so the updates will take effect immediately when the utility executes. On some systems, the System BIOS, BMC Op Code, SDR and BMC Platform Information Area (PIA) updates are programmed into their respective secondary flash areas and the utility sets an internal flag in the BIOS and BMC to indicate that the update occurred. After a system reset, the newer version of the System BIOS, BMC, and SDRs are validated and then activated.

Refer to the following table to determine when the firmware update takes effect for each Intel Server Board or System.

Intel® Server Boards or System

Firmware Component S7000FC4UR S3000AH, S3000PT S3200SH, X38ML S5400SF S5000PSL,S5000PAL, S5000XSL,S5000XAL, S5000XVN,S5000VCL
BIOS Next Reboot Immediately Immediately Next Reboot Next Reboot
BMC Next Reboot Not Supported Immediately Next Reboot Next Reboot
SDR Next Reboot Not Supported Immediately Next Reboot Next Reboot
FRU Immediately Not Supported Immediately Immediately Immediately
HSC* Immediately Not Supported Not Supported Immediately Immediately
Local Control Panel (LCP)* Immediately Not Supported Not Supported Not Supported Immediately
Intel® Remote Management Module 1* Not Supported Not Supported Not Supported Not Supported Immediately
Intel® Remote Management Module 2** Not Supported Not Supported Not Supported Not Supported Not Supported

* HSC, LCP & RMM 1-> Some components are optional or configuration dependent and may not be present on all systems. HSC updates are not supported on expander HSC backplanes

**Intel RMM2 firmware is updated using update utilities provided with the Intel RMM2 firmware updates

This applies to:
IntelŽ Server Board S3000AH
IntelŽ Server Board S3000PT
IntelŽ Server Board S3200SH
IntelŽ Server Board S5000PAL
IntelŽ Server Board S5000PSL
IntelŽ Server Board S5000VCL
IntelŽ Server Board S5000VSA
IntelŽ Server Board S5000XAL
IntelŽ Server Board S5000XSL
IntelŽ Server Board S5400SF
IntelŽ Server Board X38ML
IntelŽ Server System S7000FC4UR
IntelŽ Server System SC5400RA
IntelŽ Server System SR1520ML
IntelŽ Server System SR1530AH
IntelŽ Server System SR1530AHLX
IntelŽ Server System SR1530CL
IntelŽ Server System SR1530HAHLX
IntelŽ Server System SR1530HCL
IntelŽ Server System SR1530HCLS
IntelŽ Server System SR1560SF
IntelŽ Server System SR2520SA
IntelŽ Workstation Board S5000XVN

Solution ID: CS-029434
Date Created: 15-Jun-2008
Last Modified: 23-Jun-2008
Back to Top