Intel® has found that RAID controllers may simultaneously mark multiple drives as failed on the above listed chassis and platforms. Drives will not operate when marked as failed. This issue has been seen while running a disk stress test with various RAID controllers and Ultra 160 drives. The problem is potentially present in all Hot Swap Controller (HSC) RAID configured applications, but it is believed that higher SCSI bus speeds increase the probability of the problem (i.e., Ultra 160 is at higher risk than Ultra 2).
Technical Advisory [PDF]
File Name: TA_403.PDF
Size: 18684 bytes
Date: 5/4/01 1:27:22 PM

Note: PDF Files require Adobe Acrobat* Reader†

† This link will take you off of the Intel Web site. Intel does not control the content of the destination Web Site.
This applies to:
|