Intel® Server System SPSH4 and SRSH4 SCSI SAFTE controller cards with hot swap controller (HSC) firmware version 0.10 (Intel part number A42862-110) may cause certain 15K and 10K RPM hard disk drives to be marked offline during system AC power on or AC power cycling (power button pressed). This condition has been reported only when 15K or 10K RPM hard disk drives are in use, and has only been seen to occur during AC power on or AC power cycling. This issue does not affect other hard disk drive speeds, and will not cause hard disk drives to be marked offline during run time operation or soft (warm) reboots. This issue is expected to occur approximately only once out of every twenty AC power cycles.
Please see the Tested Hardware and Operating System List for a list of supported hard drives.
Technical Advisory 698 [PDF]
File Name: ta6982spsh4srsh4hsc011.pdf
Size: 23,676 bytes
Date: June 8, 2004
File Revision: TA-698-2

Note: PDF Files require Adobe Acrobat* Reader†

† This link will take you off of the Intel Web site. Intel does not control the content of the destination Web Site.
This applies to:
|