Search
Support & Downloads
Server Products
Intel® Server Board SE7500CW2
How Do I Ensure Redundancy Across Promise* ATA 100 RAID Controllers?

When creating a RAID array using the Promise* ATA 100 RAID controller, keep in mind redundancy can only be obtained when your drives are spread across the two channels. You cannot obtain redundancy if you have a Master / Slave configuration on a single channel. In order for a redundant array to be valid, a Master / Master configuration should be used or a Master with Slave & Master with Slave configuration.

If you have a Master / Slave on a single channel and the master driver goes off-line, your slave drive will also go off-line. Data will not be lost, but your RAID array will be unavailable and this could cause unwanted downtime on your server.

This applies to:
Intel® Server Board SE7500CW2



Solution ID: CS-006880
Date Created: 16-Nov-2003
Last Modified: 17-Nov-2003
Back to Top