The chassis listed below were tested to determine whether they provide adequate airflow to keep critical server components within the individual manufacturer's temperature specifications.

The following links will take you off of the Intel web site. Intel does not control the content of these linked Web sites.

Note: Additional chassis undergoing test. Results will be posted as available.

Supplier (1) Model # (2) Type (3) Power Supply (4)

Thermal Test Level (5)

Intel® Xeon® Supported Processors

Drive Support (6)

EMC Reports

Emission Immunity
Intel SR1350-E (SR1350E) R1U -- -- 2.8 C    
Intel SR1350-E (SR1350ENA) R1U -- -- 2.8 C    
Intel SC5200 (KHD3BASE450) FT/R5U -- 3 3.20 B,C Yes Yes
Intel SC5200 (KHD3HSRP650) FT/R5U R/D,H/S 3 3.20 A Yes Yes
Intel SC5200 (KHD3HSRP650R) R5U R/D,H/S 3 3.20 A Yes Yes
Intel SC5200 (KHDRP450) FT/R5U R/D,H/S 3 3.20 B,C Yes Yes
AIC RMC1H2-6I-DK8T 1U -- 1 3.06 C No No
AIC RMC1Q2 R1U -- 3 3.06 A    
AIC RMC3F2 3U     3.06 A,B    
AIC RMC2Q2 R2U -- 3 3.06 C    
Aopen H800A R5U/MT -- 3 3.06 C    
Chenbro RM212 R2U -- 3 3.06 C    
Chenbro SR101 FS -- 3 3.06 C    
Chenbro SR102 FS R/D 3 3.06 C    
CiDesign RS1400 R1U -- 2 3.06 A    
CiDesign RS2100i R2U -- 3 3.06 A    
CiDesign RS4100i R4U -- 3 3.06 A    
Evercase ECS5000LX MT/5U -- 3 3.06 C    
Evercase R9112B-S35 1U -- 2 2.80 C    
Guangshing Industrial GHI-104DX R1U -- 2 2.4 C    
MaCase KA-036G FT H/S 3 3.06 C    
MaCase KA-066G FS H/S 3 2.8 C    
IW-R3000 IW-R3000 MT/5U H/S 3 3.06 C    
Yeong Yang YY-W201 MT -- 3 2.8 C    

Notes:

Additional chassis undergoing test. Results will be posted as available.

(1) Third party names and brands are the property of their respective owners.

(2) All vendors project providing a minimum of 800ma of 5V power for standby required for Wake on LAN* (WOL)and Emergency Management Port (EMP) support. Customers should refer to the chassis specification to assure the power supply has been upgraded in the chassis.

(3) Chassis Legend:

  • R = Rack (U is multiple of 1.75 inches)
  • FT = Full Tower
  • FS = File Server
  • MT = Mid Tower
(4) Power Supply:
  • - = Single
  • R/D = Redundant
  • H/S = Hot Swap Redundant

(5) Thermal test level refers to the highest level of testing that successfully completed Intel's thermal testing. The chassis configuration summary is provided below:

Level Processor Memory Disk Type # of Disk
1 2 x 2.4 or 2.8 or 3.06 Ghz Intel® Xeon® Processors Fully loaded 128MB DDR 266 Seagate* SCA ST318406LC 1
2 2 x 2.4 or 2.8 or 3.06 Ghz Intel® Xeon® Processors Fully loaded 128MB DDR 266 Seagate* ATA ST380021A,
Seagate* SCA ST318406LC
2
3 2 x 2.4 or 2.8 or 3.06 or 3.20 Ghz Intel® Xeon® Processors Fully loaded 128MB DDR 266 Seagate* ATA ST380021A,
Seagate* SCA ST318406LC
3
(6) Drive support Option Legend:

Option Designator Supported Drive Type
A SCSI (SCA)
B Docking ATA
C Cabled (SCSI or ATA)

The testing information is provided as a guide for the reseller in choosing chassis products that are compatible with the Intel® Server Board SE7501HG2. The reseller is encouraged to test the chassis products in specific configurations.

IMPORTANT INFORMATION AND DISCLAIMERS: The content of the website links located in the tested chassis list is not controlled by Intel. These links are being offered for your convenience and should not be viewed as an endorsement by Intel of the content, products, or services offered there. This listing is not intended to be all inclusive, nor is it an endorsement by Intel; it only represents chassis Intel has examined to date. Users of this list are reminded to check with the chassis manufacturer to get latest model specifications and ensure a particular chassis model is adequate for the user's intended purposes. This list is subject to change at any time. Check this web site regularly for updates. For purposes of future server board introductions, Intel may test current and additional chassis, which may result in a revision of this chassis list. Intel reserves the right to modify this document at any time without notice. Intel assumes no responsibility for any errors which may appear in this document, nor does it make any commitment to update the information contained in it. Intel disclaims any liability or obligation for damages of any kind arising out of the application or use of the information contained in this document.

INTEL DISCLAIMS ALL WARRANTIES AND GUARANTEES, EXPRESS, IMPLIED OR OTHERWISE, ARISING FROM OR CONCERNING THE CONTENTS OF THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF ANY THIRD PARTY. INTEL MAKES NO CLAIMS OF COMPLIANCE WITH ANY GOVERNMENTAL REGULATORY AGENCY.

Intel does not convey any license, express, implied or statutory, by estoppel or otherwise, arising under its intellectual property rights, nor under the rights of others. This information is for reference use by PC integrators only. PC integrators are not authorized to refer to Intel's testing or reporting activities in advertising or any other manner.


   This link will take you off of the Intel Web site. Intel does not control the content of the destination Web Site.

This applies to:
Intel® Server Board SE7501HG2



Solution ID: CS-007319
Date Created: 01-Dec-2003
Last Modified: 12-Oct-2005
Back to Top