Search
Support & Downloads
All of Support
This Category
This Product
Server Products
Intel® Storage Server SSR212MC2
Hot swap system fan support

Intel® Storage Server SSR212MC2 and SSR212MC2R manufactured before July 2007 do not support hot swap system fans. Systems manufactured July 2007 or after, provided hot swap fan capability.

Non-hot swap fan support:

  • SSR212MC2 with MM# 890053
  • SSR212MC2R with MM# 890027

Non-hot swap system fans have blue colored touch points, not green (which indicates hot swap).

For non-hot swap fan systems, the storage server may corrupt or loose data contained on the data hard disk drives, if a system fan is removed with power applied (hot swapped).

The workaround for this issue is to shut the system down to replace a failed system fan.

NOTE:
If a non-hot swap fan is mistakenly removed with power applied to the system, make sure and power down the system before reinserting the fan.


Hot swap fan support:

  • SSR212MC2 with MM# 891935
  • SSR212MC2R with MM# 891934
  • SSR212MC2BR with MM# 893628 or later
  • SSR212MC2RBR with MM# 893519 or later

This applies to:
Intel® Storage Server SSR212MC2
Intel® Storage Server SSR212MC2R

Solution ID: CS-026491
Date Created: 09-May-2007
Last Modified: 21-Jul-2008