Symptom:
User installed a 50-MHz IntelSX2 OverDrive® processor and received
the following error before the system counted memory:
A20 handler error
The computer then locks up.
Description:
The switches were set for an Intel487 SX-33 and for the extra upgrade
socket. If the input speed is not set correctly the OverDrive processor
could have problems with the A20 handler and generate the above error.
Solution:
Set the speed to 25 MHz.
This applies to:
|